Detectors
Photodiode array detection
The photodiode array detector (DAD) is an advanced type of UV detector. Depending on the wavelength, a tungsten lamp and a deuterium lamp are used as light sources. The polychromatic light beam is focused on a flow-cell (volume 8–13 μL) and subsequently dispersed by a holographic grating or quartz prism . The spectral light then reaches a chip that contains 100–1000 light-sensitive diodes arranged side by side. Each diode only registers a well-defined fraction of the information and in this way all wavelengths are measured at the same time. Note that although having more diodes in an array increases the resolution of UV spectra, it lowers the absolute sensitivity since less radiation is absorbed by each individual diode. The wavelength resolution of up-to-date detectors is of the order of 1 nm per diode, with a wavelength accuracy of better than 1 nm and a sensitivity below 10 4 absorbency units. All operations of the detector are controlled by a computer: correction of fluctuations of the lamp energy, collection of signals (Iλ) from all the diodes, storage of the data of the mobile phase (I0λ, measured at the start of the chromatogram) and calculation of the absorbance according to the Beer–Lambert law from Iλ to I0λ. The number of spectra recorded per second can be chosen from between 0.1 and 10; usually one spectrum per second is optimal with respect to chromatographic resolution and noise. At the end of the run, a three-dimensional Spectro chromatogram (absorbance as a function of wavelength and time) is stored on the computer and can be evaluated qualitatively and quantitatively. A detailed description of the operation of DAD is given in Huber and George (1993).
DAD offers several advantages. Knowledge of the spectra of compounds of interest enables interfering peaks to be eliminated such that an accurate quantification of peaks of interest can be achieved despite less-than-optimal resolution. Simultaneous detection at two wavelengths allows calculation of an absorbance ratio. If this ratio is not constant across a peak, the peak is not pure, regardless of its appearance. An additional advantage of DAD is the subtraction of a reference wavelength. This reduces baseline drift during gradient elution. HPLC-DAD systems linked to libraries of UV spectra are particularly useful in clinical and forensic toxicology in screening for drugs in biological samples and their use in this context is described in detail later (F. Pragst and M. Herzler, personal observations).
0
0
الاكثر قراءة في تحليل السموم
اخر الاخبار
اخبار العتبة العباسية المقدسة